Session logging
| What you want to keep | Where to start |
|---|---|
| Every connection, including reconnects | Options → Session Logging… → Log all sessions automatically |
| Output from one connection, starting now | File → Start Session Log |
| Part of an investigation with a tag and a comment | File → Start Tagged Session Log… |
Automatic logging starts off. Once enabled, it starts a separate session log in each open terminal and each new connection. A manual choice lasts until disconnect. When the tab reconnects, it follows the automatic setting again and starts a fresh file if enabled.
A tagged session log runs independently. Pick an existing rheaCRT tag or enter a new one, add an optional comment, and choose Start Log. A grouped tab fills in its group tag for you. You can change it before starting the log. Choose Stop Tagged Session Log to finish the interval while the regular session log continues.
The File menu controls the selected tab. To control another connection while you keep working in the current one, right-click the other tab. Choose Start Session Log or Start Tagged Session Log…. The same menu lets you stop either log. An active tagged interval shows Tagged log on its tab. You can also focus a tab and press Shift+F10 to open its menu.
A VLAN migration
Before changing a switch port, start a Tagged Session Log named VLAN migration. Add a comment such as Move the access port to VLAN 120, run your checks before and after the change, then stop the tagged log. Use the same tag when you work on the next switch so you can find both files by name.
A proposed Binaric integration would let you attach that same tag to a reachability event and review it alongside the switch transcript. The current workflow keeps the tag local to rheaCRT.
Name the files
Open Options → Session Logging… to set the filename template. The default is %H-%Y%M%D-%h%m%s-%t. For example, a connection to edge-sw1 at 09:07:03.042 on April 5, 2026 produces edge-sw1-20260405-090703-042.log. Tagging a log vlan-change adds -vlan-change before the extension. Include %T to place the tag elsewhere. The dialog previews both filenames before you save.
| Variable | Value |
|---|---|
%H | Host, or the session name for a local shell or serial console |
%S, %P | Session name and connection port when available |
%Y, %M, %D | Four-digit year, month and day |
%h, %m, %s, %t | Local hour, minute, second and three-digit millisecond |
%T, %% | Selected tag and literal percent sign |
The template names a file within rheaCRT’s log folder. If two connections would get the same filename, rheaCRT gives the new log a distinct name. Filename and formatting changes apply to the next log you start.
Raw output and readable notes
The .log file holds the exact bytes delivered to the terminal, including ANSI colour and cursor commands, line endings, backspaces and bytes outside UTF-8. An SSH log starts with shell output after authentication. A login attempt that ends earlier can leave an empty raw file and a start header. A password typed at a hidden prompt stays out. A secret printed by the device is part of its output.
By default the matching .notes.txt file opens with the local start date and time, followed by readable output. Edit Header template to change that first line. For example, Started %Y-%M-%D %h:%m:%s on %H includes the device name. A tagged log’s notes can also carry your comment.
Timestamp each output line starts off. Enable it to prefix each line with the local time when the readable writer processes its first text. Under a disk backlog, this can be later than the time the device sent it. To keep just a raw log, clear Include start header, leave line timestamps off, and omit the comment. Notes are intended for line-oriented command output. Interactive full-screen programs may redraw earlier rows.
Retrieve a tab’s log
Right-click a tab and choose Session Log Files… or Tagged Session Log Files…. Each menu follows the latest file of its kind for that tab. It works while recording, after stopping, and after disconnecting. When a reconnect starts a new regular log, the tagged menu still points to the preceding interval until you start another one.
| Action | Result |
|---|---|
| Show in Explorer | Opens the folder with the first raw file selected. |
| Copy Path | Copies the full path of each raw file, one per line, in recording order. |
| Copy File | Puts the raw files on the Windows clipboard so you can paste them into a folder. |
| Copy Log Text | Copies the readable output, including any saved header, comment and timestamps. For raw-only logs, rheaCRT renders the terminal text before copying. |
Copy Log Text reads up to 32 MiB across the parts of the chosen format. Use Copy File for larger recordings. Closing the tab or restarting rheaCRT clears its file menu history. The files remain in the logs folder.
Find older logs and check errors
Choose File → Open Session Logs Folder, or click the logging indicator in the footer. Regular logs are under Sessions and tagged logs under Tagged. Earlier releases used Named and Captures. Existing files stay in those folders.
Raw logs roll to numbered parts at 16 MiB. Joining the parts in numeric order reconstructs the original stream. Readable files roll independently.
Each rheaCRT process can record 32 logs at once. Recording both kinds on 16 sessions uses all 32 slots. Enabling readable copies for all of them opens up to 64 files. Each file has its own queue bounded at 2 MiB. A slow readable writer can stop with a warning while the raw file continues. If a raw writer stops, the footer reports the error and the terminal stays connected. Free disk space or stop another log if needed, then start a fresh log.